ASTM B368-97 pdf free

04-17-2021 comment

ASTM B368-97 pdf free.Standard Test Method for Copper-Accelerated Acetic Acid-Salt Spray (Fog) Testing (CASS Test).
Cleaning Tested Specimens—Unless specified in thespecifications covering the material or product being tested,carefully remove specimens at the end of the test, rinse gentlyin clean,running,warm water (38C, max) to remove saltdeposits from their surfaces, and then dry immediately. To drythe specimens use a stream of clean, compressed air at 0.25 to0.30 MPa gage pressure.
Calibration of Corrosive Conditions—This procedurefor calibration and standardization of the corrosive conditionswithin the cabinet involves exposure of nickel test panels anddetermination of their mass loss in a specified period of time.This may be done monthly or more frequently to make sure thecabinet is operating within the limits specified in 8.7.4.Use nickel panels that are 7.5 by 10 cm, approximately0.09 cm thick, and made from the higher carbon grade (0.15%max) given in Specification B 162. Place one weighed nickel test panel in each corner ofthe cabinet with the 10-cm length inclined 30° to the verticalusing plastic supports that are about 1.5 by 4 by 7.5 cm. Thefour test panels should be on the inboard side of the condensate collectors parallel to the cabinet length. Make sure the top ofthe panels are at the same level as the top of the condensatecollectors.
8.7.3 Expose the test panels to 22 h of CASS testing,recording test operating conditions on the data sheet as usual.Remove the panels from the cabinet and rinse each in reagentgrade water (see Specification D 1193,Type IV) to removesalt. Immerse each panel in 20% by volume hydrochloric acidprepared with distilled water for 2 min at 20 to 25°C usingnickel-copper alloy 400 (UNS N04400) tongs.The tongs maybe nonmetallic or another material that will not affect the massloss of the nickel by galvanic action. Rinse each panel in waterat room temperature and then in warm (38°C) flowing water.Dry panels in an oven at 100C for 10 min.Allow the panelsto reach room temperature and weigh immediately on ananalytical balance.
Determine the mass loss of each panel by subtractingits weight after exposure from its initial weight. Determine thecorrosive loss by dividing the mass loss by the area of one faceof the test panel (77.5 cm2). The corrosive rate shall be 0.45 to0.85 mg/cm2 to satisfy the requirements of this method.A careful and immediate examination shall be made forthe extent of corrosion of the dry-test specimens; or for otherfailure, as required by the specifications covering the materialor product being tested; or by agreement between the purchaserand the supplier.The following information shall be recorded, unlessotherwise prescribed in the specifications covering the materialor product being tested:The title,designation and year of issue of thismethod.The salt, water, copper chloride, and acetic acid usedin preparing the salt solution,All readings of temperature within the exposure zoneof the chamber.ASTM B368 pdf download.

Download infomation Go to download
Note: Can you help me share this website on your Facebook or others? Many thanks!
AS ISO ASTM 52904:2021 pdf free Free AS Standards

AS ISO ASTM 52904:2021 pdf free

AS ISO ASTM 52904:2021 pdf free.Additive manufacturing - Process characteristics and performance - Practice for metal powder bed fusion process to meet critical applications. 5 Feedstock and Powder Batches 5.1 The material supplier shall package the powder...
Get More
AS ISO/ASTM 52901:2021 pdf free Free AS Standards

AS ISO/ASTM 52901:2021 pdf free

AS ISO ASTM 52901:2021 pdf free.Additive manufacturing - General principles - Requirements for purchased AM parts. 4.3.3 Tolerances The tolerances shall be specified (e.g. general tolerances, see ISO 2768-1 and ISO 2768-2, and/or specific, ISO 1101), including...
Get More
AS 2455.2:2019 pdf free download Free ASTM Standards

AS 2455.2:2019 pdf free download

AS 2455.2:2019 pdf free download.Textile floor coverings - Installation practice Part 2: Carpet tiles. 4 Pre-laying requirements 4.1 General Pre-laying requirements shall be in accordance with AS 2455.1. Prior to commencement, it should be ascertained that carpet...