AS/NZS 3122:2015 pdf free.Approval and test specification – Socket-outlet adaptors.
4.2 Non-resireablc socket-outlet adaptor
A socket-outlet adaptor so constructed that it forms an integral unit with any flexible cable or cord. such that—
(a) any flexible cable or cord cannot be detached from the accessory without making the accessory useless: or
(b) any flexible cord cannot be replaced by hand or by using a general purpose tool.
4.3 Plug portion
The portion of the socket-outlet adaptor which carries the pins intended for making a detachable connection with the contacts of a socket-outlet. For socket-outlet adaptors incorporating flat-pins, the ‘plug portion’ includes all parts dimensioned in accordance with
AS[NZS 3112.
4.4 Rewireable socket-outlet adaptor
A socket-outlet adaptor so constructed that any flexible cable or cord can be replaced.
4. Socket-outlet adaptor
An accessory for insertion into a socket-outlet and containing metal contacts, to accommodate one or two plugs, or a flexible cord and one plug.
4.6 Socket portion
The outlet portion of the socket-outlet adaptor which carries the contacts intended for
making a detachable connection with the pins of a plug.
4.7 Outlet
A socket outlet, flexible cord or facilities for the connection of a flexible cord.
S PROHIBITEL) FEATURES
Socket-outlet adaptors shall not—
(a) have more than two outlets:
(b) have more than one outlet for a flexible cord;
(c) have an outlet in the form of a lampholder:
(d) be capable of insertion in a lampholder;
(e) incorporate a plug portion having only two pins and an outlet providing for the connection of other than a 2-pin plug or a 2-core flexible cord;
(I’) incorporate a plug portion having an earthing pin and an outlet not provided with an earthing terminal or earthing contact for each plug configuration able to be used with the adaptor:
(g) incorporate any fuse or thermal overload device in series with an outlet:
(h) have an outlet providing for the connection of a plug having a current rating exceeding that of the plug portion of the adaptor;
(i) have an outlet with a current rating exceeding 20 A;
(j) have an outlet with a voltage rating exceeding low voltage; and
(k) have an outlet with polarity differing from that of the plug portion of the adaptor.
6 EXTRA-LOW VOLTAGE TYPES
Extra-low voltage socket-outlet adaptors are not required to comply with Clauses I 5 and 17.AS/NZS 3122 pdf download.