IEEE C57.94-1982 pdf free.IEEE Recommended Practice for Installation,Application, Operation, andMaintenance of Dry-Type General Purpose Distribution and Power Transformers.
IEEE C57.94 following American National Standards referred to in this recommended practice are superseded by arevision approved by the American National Standards Institute, the latest revision shall be used.
[1]ANSI C2-1981, National Electrical Safety Code2
[2]ANSI C57.12.50-1981,American National Standard Requirements for Ventilated Dry-Type DistributionTransformers 1 to 500kVA,Single Phase: and 15—500kVA,Three-Phase with High Voltage601—34500 Volts, LowVoltage 120——600 Volts
[3]ANSI C57.12.51-1981 American National Standard Requirements for Ventilated Dry-Type Power Transformers,501 kVA and Larger, Three-Phase, with High-Voltage 601 to 34 500 Volts, Low-Voltage 208Y/120 to 4160 Volts
[4]ANSI C57.12.52-1981,American National Standard Requirements for Sealed Dry-Type Power Transformers,501 kVA and Larger, Three-Phase, with High-Voltage 601 to 34500 Volts, Low Voltage 208Y/120 to 4160 Volts
[5]ANSI C57.12.70-1978,American National Standard Terminal Markings and Connections for Ditribution andPower Transformers
[6]ANSI C57.12.80-1978,American National Standard Transformer Terminology
[7]ANSI C57.96-1959,American National Standard Guide for Loading Dry-Type Distribution and PowerTransformers (Appendix to ANSI C57.12 standards)
[8] ANSI C62.2-1980,American National Standard Guide for Application of Valve-Type Lightning Arresters forAlternating Current Systems
[9] ANSI C84.1-1977,American National Standard Voltage Ratings for Electric Power Systems and Equipment(60 Hz) (includes supplement ANSI C84.1a-1980)
[10] ANSIIEEE C57.12.01-1979,IEEE Standard General Requirements for Dry-Type Distribution and PowerTransformers.
[11]ANSIVIEEEC57.12.91-1979,IEEE Standard Test Code for Dry-Type Distribution and Power Transformers[12]ANSI/IEEE Std 100-1977,IEEE Standard Dictionary of Electrical and Electronics Terms
[13] ANSINEMA ST 20-1972(R1978),American National Standard for Dry-Type Transformers for GeneralApplications
[14]ANSI/NFPA 70-1981,National Electrical Code3
[15] IEEE Std 4-1978,IEEE Standard Techniques for High Voltage Testing
[16] IEEE Std 142-1972,IEEE Recommended Practice for Grounding of Industrial and Commercial Power Systems(IEEE Green Book)
[17]ANSIIEEE C57.98-1968,IEEE Guide for Transformer Impulse Tests(Appendix to C57.12.90)
ventilated dry-type transformer: A dry-type transformer which is so constructed that the ambient air may circulatethrough its enclosure to cool the transformer core and windings.
nonventilated dry-type transformer: A dry-type transformer which is so constructed as to provide no intentionalcirculation of external air through the transformer, and operating at zero gauge pressure.
sealed dry-type transformer: Self-Cooled. A dry-type self-cooled transformer with a hermetically sealed tank.IEEE C57.94 pdf download.