BS ISO 23978:2020 pdf free

04-24-2021 comment

BS ISO 23978:2020 pdf free.Natural gas — Upstream area — Determinationof composition by Laser Raman spectroscopy.
This document describes a laser Raman spectroscopy method for the quantitative determination ofchemical composition of natural gas in upstream area.
The following documents are referred to in the text in such a way that some or all of their contentconstitutes requirements of this document. For dated references, only the edition cited applies. Forundated references, the latest edition of the referenced document(including any amendments) applies.ISO 6142-1,Gas analysis – Preparation of calibration gas mixtures — Part 1: Gravimetric method for Class I mixtures.
ISO 6144,Gas analysis —Preparation of calibration gas mixtures —Static volumetric methodISO 6145,Gas analysis —Preparation of calibration gas mixtures using dynamic methodsISO 10715, Natural gas — Sampling guidelines.
ISO 11095, Linear calibration using reference materials.
sFor the purposes of this document, the following terms and definitions apply.
Raman effect:process,in which photons from a light source are absorbed by the electrons surrounding polyatomicmolecules and result in a new photons being emitted at wavelengths higher or lower than the sourcephoton wavelength
Note 1 to entry: The resulting wavelength changes are called Raman shifts. The Raman shifts are determined bythe vibrational and rotational frequencies of the atomic bonds within each molecule.multichannel photodetector:photosensitive semiconductor device that transports electric charge from one capacitor to another,allowing serial output of parallel data, typically used for digital image capture.
The type of Raman gas analyser is selected according to the types of gases and the natural gasconcentration ranges of interest. The base analyser unit contains a laser,optical path control, gasdetection chamber, photon detection and processing, signal processing,and human/machine interface.The analyser should have sensitivity sufficient to detect the components in the analytical range givenin Table i. It should keep a stable state after zero calibration.The laser shall have a narrow-enough line width with a stable-enough power output and wavelength soas not to compromise the generation and analysis of the Raman spectra. Laser power should be highenough to ensure sufficient sensitivity.BS ISO 23978 pdf free.

Download infomation Go to download
Note: Can you help me share this website on your Facebook or others? Many thanks!
AS ISO ASTM 52904:2021 pdf free Free AS Standards

AS ISO ASTM 52904:2021 pdf free

AS ISO ASTM 52904:2021 pdf free.Additive manufacturing - Process characteristics and performance - Practice for metal powder bed fusion process to meet critical applications. 5 Feedstock and Powder Batches 5.1 The material supplier shall package the powder...
Get More
AS ISO/ASTM 52901:2021 pdf free Free AS Standards

AS ISO/ASTM 52901:2021 pdf free

AS ISO ASTM 52901:2021 pdf free.Additive manufacturing - General principles - Requirements for purchased AM parts. 4.3.3 Tolerances The tolerances shall be specified (e.g. general tolerances, see ISO 2768-1 and ISO 2768-2, and/or specific, ISO 1101), including...
Get More
AS ISO 16809:2020 pdf free Free AS Standards

AS ISO 16809:2020 pdf free

AS ISO 16809:2020 pdf free.Non-destructive testing — Ultrasonic thickness measurement. 5 General requirements 5.1 Instruments The following types of instruments shall be used to achieve thickness measurement: a) dedicated ultrasonic thickness measurement instruments with numerical display showing...
Get More

LEAVE A REPLY

Anonymous netizen Fill in information