AS 3856.2:2021 pdf free.Hoists and ramps for people with disabilities – Vehicle fitted Part 2: Fitting requirements.
11.6 Circuits
All circuits shall be protected with a suitably rated current overload device (i.e. fuse).
12 Warning system
For Type A, B, C and D appliances which are fitted to the side of a vehicle, a means shall be provided to warn the driver of the vehicle that the appliance is not stored.
NOTE This may take any form, including a visual or audio warning or a safety interlock to prevent movement of the vehicle.
13 Securement of ramps
13.1 Attachment to the vehicle
Ramps shall be attached to the vehicle in such a manner that they cannot be displaced during use in accordance with Appendix C.
13.2 Storage in the vehicle
Detachable ramp(s) when not in use shall be securely stored in the vehicle. Ramps shall be stored in a manner that will prevent a loading of 20 times the weight of the ramp, applied in any horizontal direction, from tearing it free.
NOTE The fitter should seek the advice of the State or Territory vehicle registration authority with regard to the fitting of anchorages.
14 Vehicle access
The installation of the appliances should not cause the occupant to alter their usual seated posture to enter and exit the vehicle.
15 Steps or stairs
The treads and risers of any steps or stairs forming part of the appliance, which are for the use of ambulatory passengers, shall conform to the requirements for stairs in AS 1428.2.
16 Performance requirements
16.1 General
16.1.1 Operation of the appliance when the vehicle is on level ground, on a gradient and at an angle
The following shall apply:
(a) The appliance shall operate when the vehicle is on level ground and on road gradients (pitch) up to 4 degrees.
(b) The appliance shall operate when the vehicle is on level ground and when the vehicle is at an angle of ± 5 degrees (vehicle roll) due to road crowns, depressions, or kerb geographics.AS 3856.2 pdf download.

Download infomation Go to download
Note: Can you help me share this website on your Facebook or others? Many thanks!
AS/NZS 60079.5:2015 pdf free Free AS Standards

AS/NZS 60079.5:2015 pdf free

AS/NZS 60079.5:2015 pdf free.Explosive atmospheres Part 5: Equipment protection by powdered filling 'q'. 4.1.1.3 Containers intended to be opened for repair Electrical equipment, parts of electrical equipment, or Ex components that are designed to be repaired shall...
Get More
AS/NZS 60079.2:2015 pdf free Free AS Standards

AS/NZS 60079.2:2015 pdf free

AS/NZS 60079.2:2015 pdf free.AUSTRALIAN/NEW ZEAL AND STANDARD Explosive atmospheres. 5 Constructional requirements for pressurized enclosures 5.1 Enclosure The pressurized enclosure shall have a degree of protection in accordance with Table 2. For Level of Protection pxb with...
Get More
AS/NZS 5263.1.3:2016 pdf free Free AS Standards

AS/NZS 5263.1.3:2016 pdf free

AS/NZS 5263.1.3:2016 pdf free.Gas appliances Part 1.3: Gas space heating appliances. 2.1 SCOPE This Clause of AS 5263.0 applies. 2.2 GENERAL DESIGN REQUIREMENTS This Clause of AS 5263.0 applies, except as modified below. 2.2.13 IJesign olappliance base...
Get More

LEAVE A REPLY

Anonymous netizen Fill in information