AS 1012.25.1:2020 pdf free.Methods of testing concrete Method 25.1: Determination of the fibre content of plastic state concrete (wash-out test).
4 Apparatus and materials
4.1 Measure
4.1.1 General
The measure shall be made of metal not less than 3 mm thick, be watertight and be sufficiently rigid to maintain its shape with rough usage. The inside surface shall be smooth and free from corrosion. The rim of the measure shall be machined to a plane surface perpendicular to the axis of the cylinder.
NOTE The measure should be provided with carrying handles.
The diameter of the measure shall be between 0.75 and 1.25 times the height.
For testing concrete with aggregates of nominal size not exceeding 40 mm, the capacity of the bowl shall be not less than 5 1.
For testing concrete with larger aggregate, a larger bowl shall be used (e.g. for concrete with maximum 75 mm nominal size aggregate). A measure of capacity not less than 10 L shall be used.
4.1.2 Volume check
The measure shall be checked at a known temperature by determining the mass in kilograms of water required to precisely fill it. Filling shall be achieved by sliding a flat glass cover plate over the overfilled measure such that no air is trapped under the cover. The capacity of the measure shall be obtained by dividing the mass of water so determined by the unit mass of water at that temperature, e.g. 997.5 kg/rn3 at 23 °C.
When compacted as per this test method, the volume of the concrete sample (‘/) shall be the same volume as that determined for the measure, expressed to the nearest 0.02 L.
4.2 Balance
A balance of sufficient capacity with a limit of performance as follows:
(a) For mass determinations greater than 2 kg, a limit of performance not exceeding ± 5 g with an accuracy of at least 1 g.
(b) For mass determinations less than 2 kg, a limit of performance not exceeding ± 0.5 g readable to 0.1 g.
4.3 Rod
The rod used for the compacting of concrete in the measure shall be a metal rod of 16 ± 1 mm in diameter, approximately 600 mm long and having at least one end tapered for a distance of approximately 25 mm to a spherical shape having a radius of approximately 5 mm.
4.4 Mallet
The mallet used in conjunction with the rod for compacting of concrete shall be fitted with a hard rubber or hard plastics head of mass approximately 0.25 kg.
4.5 Scoop
A scoop, shovel or other receptacle used for sampling concrete, with a capacity of not less than 1 L.
4.6 Glass cover plate
A flat glass or plastic cover plate shall be used in the volume check of the measure.
4.7 Vibrators
Internal vibrators used for the compacting of concrete shall have a frequency of vibration or at least
115 Hz. The outside diameter of the vibrating element inserted into the concrete shall be not more than
20 % of the least dimension of the measure. The outside diameter shall be at least 15 mm.
External vibrators used for the compacting of concrete shall have a frequency of vibration of at least 50 Hz. The measure shall be clamped securely to the vibrator.AS 1012.25.1 pdf download.

Download infomation Go to download
Note: Can you help me share this website on your Facebook or others? Many thanks!
AS/NZS 60079.5:2015 pdf free Free AS Standards

AS/NZS 60079.5:2015 pdf free

AS/NZS 60079.5:2015 pdf free.Explosive atmospheres Part 5: Equipment protection by powdered filling 'q'. 4.1.1.3 Containers intended to be opened for repair Electrical equipment, parts of electrical equipment, or Ex components that are designed to be repaired shall...
Get More
AS/NZS 60079.2:2015 pdf free Free AS Standards

AS/NZS 60079.2:2015 pdf free

AS/NZS 60079.2:2015 pdf free.AUSTRALIAN/NEW ZEAL AND STANDARD Explosive atmospheres. 5 Constructional requirements for pressurized enclosures 5.1 Enclosure The pressurized enclosure shall have a degree of protection in accordance with Table 2. For Level of Protection pxb with...
Get More
AS/NZS 5263.1.3:2016 pdf free Free AS Standards

AS/NZS 5263.1.3:2016 pdf free

AS/NZS 5263.1.3:2016 pdf free.Gas appliances Part 1.3: Gas space heating appliances. 2.1 SCOPE This Clause of AS 5263.0 applies. 2.2 GENERAL DESIGN REQUIREMENTS This Clause of AS 5263.0 applies, except as modified below. 2.2.13 IJesign olappliance base...
Get More

LEAVE A REPLY

Anonymous netizen Fill in information