AS ISO 3164:2020 pdf free.Earth-moving machinery – Laboratory evaluations of protective structures – Specifications for deflection-limiting volume.
4 DLV dimensions, use and accuracy
4.1 The dimensions of the orthogonal DLV shall be as shown in Figure 1 and the dimensions of the rounded DLV as shown in Figure 2.
4.2 The dimension from the SIP to the rear boundary of the DLV assumes that the seat has 150 mm fore-aft adjustment. The 210mm dimension shall be reduced from 210mm to 135 mmii the seat does not have any fore—aft adjustment. lithe fore—aft seat adjustment is less than 150 mm, the 210 mm dimension shall be reduced by one half of the difference between 150 mm and the actual fore—aft seat adjustment.
4.3 ROPS (roll-over protective structure) and TOPS (tip-over protective structure) testing shall use either the rounded or the orthogonal DLV. FOPS (falling-object protective structure) testing shall use the orthogonal DLV or the rounded DLV with an added orthogonal top head plane.
4.4 During lateral loading for TOPS and ROPS testing, it is permissible for the upper portion of the DLV to be rotated laterally about the SIP up to 15° (see Table 1). During longitudinal loading for TOPS and ROPS testing, it is permissible for the upper portion of the DLV to be rotated forwards about the LA up to 15°. See the examples given in Figure 4. The portion below the SIP of the DLV does not rotate. If there is interference with any machine component, rotation of the DLV shall be limited to the angle at which the interference occurs.
4.5 All linear dimensions of the DLV shown in Figures 1 and 2 shall have a tolerance of ±5 mm. The accuracy of locating the DLV with respect to the SIP shall be ±13 mm, horizontally and vertically. The accuracy of the rotation shall be ±10.
5 Location of DLV
5.1 The DLV shall be located using the SIP, as defined in ISO 5353, as the reference point (see Figures 1 and 2).AS ISO 3164 pdf download.

Download infomation Go to download
Note: Can you help me share this website on your Facebook or others? Many thanks!
AS/NZS 60079.5:2015 pdf free Free AS Standards

AS/NZS 60079.5:2015 pdf free

AS/NZS 60079.5:2015 pdf free.Explosive atmospheres Part 5: Equipment protection by powdered filling 'q'. 4.1.1.3 Containers intended to be opened for repair Electrical equipment, parts of electrical equipment, or Ex components that are designed to be repaired shall...
Get More
AS/NZS 60079.2:2015 pdf free Free AS Standards

AS/NZS 60079.2:2015 pdf free

AS/NZS 60079.2:2015 pdf free.AUSTRALIAN/NEW ZEAL AND STANDARD Explosive atmospheres. 5 Constructional requirements for pressurized enclosures 5.1 Enclosure The pressurized enclosure shall have a degree of protection in accordance with Table 2. For Level of Protection pxb with...
Get More
AS/NZS 5263.1.3:2016 pdf free Free AS Standards

AS/NZS 5263.1.3:2016 pdf free

AS/NZS 5263.1.3:2016 pdf free.Gas appliances Part 1.3: Gas space heating appliances. 2.1 SCOPE This Clause of AS 5263.0 applies. 2.2 GENERAL DESIGN REQUIREMENTS This Clause of AS 5263.0 applies, except as modified below. 2.2.13 IJesign olappliance base...