BS EN IEC 63056:2020 pdf free.Secondary cells and batteries containing allkaline or other non-acid electrolytes一Safety requirements for secondary lithium cells and batteries for use in electrical energy storage systems.
The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
IEC 60050-482, International Electrotechnical Vocabulary (1EV) — Part 482: Primary and secondary cells and batteries (available at http://www.electropedia.org/)
IEC 60695-10-2. Fire hazard testing — Part 10-2: Abnormal heat — Ball pressure test method
IEC 60695-11-10. Fire hazard testing — Part 11-10: Test flames — 50 W horizontal and vertical flame test methods
IEC 60950-1:2005. Information technology equipment — Safety — Part 1: General requirements
IEC 62619. Secondary cells and batteries containing alkaline or other non-acid electrolytes — Safety requirements for secondary lithium cells and batteries, for use in industrial applications
IEC 62620:2014, Secondary cells and batteries containing alkaline or other non-acid electrolytes — Secondary lithium cells and batteries for use in industrial applications
ISOIIEC Guide 51, Safety aspects — Guidelines for their inclusion in standards
3 Terms and definitions
For the purposes of this document, the terms and definitions given in IEC 60050-482, lSO/IEC Guide 51. and the following apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
• IEC Electropedia: available at http://www.electropedia.org/
• ISO Online browsing platform: available at http://www.iso.org/obp
safety freedom from unacceptable risk
Battery systems and the cells they contain shall comply with the applicable general safety considerations of IEC 62619. Within the standard temperature range, secondary cells can be charged at the maximum charge current, which is specified from a safety point of view. Lithium-ion cells shall always be operated within the operating region values and the storage conditions specified by the manufacturer.
The safety of lithium secondary cells and battery systems requires the consideration of two sets of applied conditions:
1) intended use;
2) reasonably foreseeable misuse.
Cells and battery systems shall be so designed and constructed that they are safe under conditions of both intended use and reasonably foreseeable misuse. It may also be expected that cells and battery systems subjected to intended use shall not only be safe but shall continue to be functional in all respects.
It is expected that cells or battery systems subjected to misuse may fail to function. However, even if such a situation occurs, they shall not present any significant hazards.
Potential hazards which are the subject of this document are:
a) fire,
b) burst/explosion,
c) critical electrical short circuit due to leakage of cell electrolyte, mechanical deformation or incorrect installation,
d) venting that continuously vents out flammable gases,
e) rupture of the casing of cell, module, battery pack, and battery system with exposure of internal components.
Conformity is checked by the tests in accordance with the appropriate standards in Clause 2.
Moving parts that have potential to cause human injuries shall be applied appropriate design and necessary measures in order to reduce the risk of injuries, including those that may be incurred during installation while cells or battery systems are being incorporated into equipment.
InsulatIon and wiring
Wiring and its insulation shall be sufficient to withstand the maximum anticipated voltage, current, temperature, altitude and humidity requirements. The design of wiring shall be such that adequate clearances and creepage distances are maintained between conductors in accordance with IEC 60950-1:2005, 3.1 and 3.2 (test temperature relies on the battery system’s operating region specified by the manufacturer). Hazardous live parts of the battery system shall be protected to avoid the risk of electric shocks, including during installation.BS EN IEC 63056 pdf download.

Download infomation Go to download
Note: Can you help me share this website on your Facebook or others? Many thanks!
BS ISO 7425-1:2021 pdf free Free BS Standards

BS ISO 7425-1:2021 pdf free

BS ISO 7425-1:2021 pdf free.Hydraulic fluid power cylinders一Dimensions and tolerances of housings for elastomer- energized, plastic-faced seals Part 1: Piston seal housings. 5.2 Axial length For axial lengths for the nominal piston diameters, see Iable3. If the...
Get More
BS EN ISO 8407-2021 pdf free download Free BS Standards

BS EN ISO 8407-2021 pdf free download

BS EN ISO 8407-2021 pdf free download.Corrosion of metals and alloys一Removal of corrosion products from corrosion test specimens. 4.1.6 The true mass of the specimen, after removal of the corrosion products, will be a value between the...
Get More

LEAVE A REPLY

Anonymous netizen Fill in information