AS/NZS 60335.2.9:2020 pdf download

09-03-2021 comment

AS/NZS 60335.2.9:2020 pdf download.Household and similar electrical appliances- Safety Part 2.9: Particular requirements for grills, toasters and similar portable cooking appliances (IEC 60335-2-9 Ed 7, MOD).
7 Marking and instructions
7.1 After the first paragraph insert the following variation:
Toasters shall be marked with the substance of the following.
The bread may burn, therefore do not use the toaster near or below combustible material, such as curtains. The toaster should be attended when in use.
7.12 In the third paragraph, delete the fourth dashed item
7.15 After the first paragraph insert the following variations:
The marking relating to toasters shall be
— for toasters fitted with a supply cord. permanently attached to the supply cord or be permanently marked on the outside of the appliance:
— for toasters provided with an appliance inlet, permanently marked on the appliance inlet or be permanently marked on the outside of the appliance near the appliance inlet.
22 Construction
22.113 Replace the text by the following.
Toasters having an ejector mechanism shall be constructed so that they switch off automatically after the normal toasting time even if the ejector mechanism is blocked by the bread.
Furthermore, toasters having an ejector mechanism shall be constructed so that they switch off automatically after the normal toasting time even if the operating lever is held down. This requirement is not applicable to toasters having an ejector mechanism if the operating lever is recessed to avoid it being inadvertently held down by a vertically moving roller door or the like.
— Compliance is checked by inspection and by the following tests for ejector mechanisms blocked by the bread and for toasters not having a recessed ape rating lever.
— The toaster is supplied at rated voltage and the ejector mechanism is prevented from releasing. On the completion of the normal toasting time, heating elements shall be automatically disconnected from the supply by at least an all-pole disconnection, micro- disconnection. However, a single pole, micro-disconnection is allowed, provided heating elements are not accessible to the test probe 12 of IEC 61032.
— For toasters not having a recessed operating lever, the test is repeated, the toaster being supplied at rated voltage with the operating lever in any position that energises the heating element and with the lever prevented from releasing. On the completion of the normal toasting time, heating elements shall be automatically disconnected from the supply by at least an all-pole disconnection, micro-disconnection. However, a single pole, microdisconnection is allowed, provided heating elements are not accessible to the test probe 12 of IEC 61032.AS/NZS 60335.2.9 pdf download.

Download infomation Go to download
Note: Can you help me share this website on your Facebook or others? Many thanks!
AS/NZS 60079.5:2015 pdf free Free AS Standards

AS/NZS 60079.5:2015 pdf free

AS/NZS 60079.5:2015 pdf free.Explosive atmospheres Part 5: Equipment protection by powdered filling 'q'. 4.1.1.3 Containers intended to be opened for repair Electrical equipment, parts of electrical equipment, or Ex components that are designed to be repaired shall...
Get More
AS/NZS 60079.2:2015 pdf free Free AS Standards

AS/NZS 60079.2:2015 pdf free

AS/NZS 60079.2:2015 pdf free.AUSTRALIAN/NEW ZEAL AND STANDARD Explosive atmospheres. 5 Constructional requirements for pressurized enclosures 5.1 Enclosure The pressurized enclosure shall have a degree of protection in accordance with Table 2. For Level of Protection pxb with...
Get More
AS/NZS 5263.1.3:2016 pdf free Free AS Standards

AS/NZS 5263.1.3:2016 pdf free

AS/NZS 5263.1.3:2016 pdf free.Gas appliances Part 1.3: Gas space heating appliances. 2.1 SCOPE This Clause of AS 5263.0 applies. 2.2 GENERAL DESIGN REQUIREMENTS This Clause of AS 5263.0 applies, except as modified below. 2.2.13 IJesign olappliance base...
Get More

LEAVE A REPLY

Anonymous netizen Fill in information