AS/NZS 60335.1:2020 pdf download.Household and similar electrical appliances – Safety.
p AZ.5.201 After Clause 5.19 add the following variation:
AZ.5.201 For appliances, other than class Ill appliances, that are intended for connection to the supply mains and that are not marked with
— a rated voltage of at least 240 V for single-phase appliances and at least 415 V for three-phase appliances, or
— a rated voltage range that includes 240 V for single-phase appliances and 415 V for three-phase appliances,
the rated voltage is equal to 240 V for single-phase appliances and 415 V for three- phase appliances, and the upper limit of the rated voltage range is equal to 240 V for single-phase appliances and 415 V for three-phase appliances. In addition, the rated current or rated power in put is equal to the calculated value corresponding to 240 V for single-phase appliances and 415 V for three-phase appliances as appropriate.
NOTE 1 Example of calculation
If the appliance is marked with a rated voltage of 230 V and a rated current A or a rated power Input It will be tested as fits marked with a rated voltage of 240 V and a rated current of A x (240230) or a rated power Input of P x (2401230)2.
p 6.1 Replace the requirement with the following variation:
Appliances shall be of one of the following classes with respect to protection against electric shock:
class I, class II. class Ill,
p 7.1 After the first paragraph of the requirement insert the following variation:
Appliances intended for connection to the supply mains, other than class Ill appliances, shall be marked with
— a rated voltage of at least:
• 230 V for single-phase appliances;
• 400 V for poly-phase appliances.
COPYRIGHT
— a rated voltage range that includes:
• 230 V for single-phase appliances:
• 400 V for poly-phase appliances.
For appliance outlets and socket outlets accessible to the user
— that are incorporated in appliances connected to the supply mains; and
— that operate at rated voltage;
the appliance shall be marked with their maximum outlet load in watts. p 7.13 Replace the requirement with the following variation:
Instructions and other text required by this standard shall be written in English. p 7.15 After the last paragraph of the requirement insert the following variation:
The marking of the maximum outlet load shall be close to the appliance outlet or socket outlet.
p 10.1 After the last paragraph of the test specification insert the following variation:
Appliance outlets and socket outlets accessible to the user
— that are incorporated in appliances connected to the supply mains: and
— that operate at rated voltage;
are not loaded during the test, however their contribution to the power input is
considered to be the marked outlet load per appliance outlet or socket-outlet.
p 11 .7 After the first paragraph of the test specification insert the following variation:
Appliance outlets and socket outlets accessible to the user are loaded with a resistive
load that gives the marked outlet load in watts.
p 11 .8 After the first paragraph of the test specification insert the following variation:
The pins of plug connectors inserted into appliance outlets accessible to the user and plugs inserted into socket outlets accessible to the user shall have a temperature rise not exceeding 45 K.
p 19.13 After the seventh paragraph of the test specification insert the following variation:
During and after the tests the no-load output voltage of an accessible safety extra-low voltage outlet or connector or Universal Serial Bus (USB) outlet shall not have increased by more than 3 V or 10% of its no-load output voltage in normal use, whichever is higher.
p 22.2 After the first paragraph of the requirement insert the following variation:
For stationary appliances permanently connected to the fixed wiring, compliance with this requirement is considered to be met if the instruction concerning disconnection incorporated in the fixed wiring is in accordance with AS/NZS 3000.
p 22.3 Replace the text with the following variation:
VOID
p 22.33 Delete the last sentence of the first paragraph of the requirement and introduce it as a new first paragraph of the requirement.
p AZ.22.201 After Clause 22.52 add the following variation:COPYRIGHT.AS/NZS 60335.1 pdf download.

Download infomation Go to download
Note: Can you help me share this website on your Facebook or others? Many thanks!
AS/NZS 60079.5:2015 pdf free Free AS Standards

AS/NZS 60079.5:2015 pdf free

AS/NZS 60079.5:2015 pdf free.Explosive atmospheres Part 5: Equipment protection by powdered filling 'q'. 4.1.1.3 Containers intended to be opened for repair Electrical equipment, parts of electrical equipment, or Ex components that are designed to be repaired shall...
Get More
AS/NZS 60079.2:2015 pdf free Free AS Standards

AS/NZS 60079.2:2015 pdf free

AS/NZS 60079.2:2015 pdf free.AUSTRALIAN/NEW ZEAL AND STANDARD Explosive atmospheres. 5 Constructional requirements for pressurized enclosures 5.1 Enclosure The pressurized enclosure shall have a degree of protection in accordance with Table 2. For Level of Protection pxb with...
Get More
AS/NZS 5263.1.3:2016 pdf free Free AS Standards

AS/NZS 5263.1.3:2016 pdf free

AS/NZS 5263.1.3:2016 pdf free.Gas appliances Part 1.3: Gas space heating appliances. 2.1 SCOPE This Clause of AS 5263.0 applies. 2.2 GENERAL DESIGN REQUIREMENTS This Clause of AS 5263.0 applies, except as modified below. 2.2.13 IJesign olappliance base...
Get More

LEAVE A REPLY

Anonymous netizen Fill in information