AS/NZS-1680.4:2017 pdf download.Interior and workplace lighting Part 4: Maintenance of electric lighting systems Superseding AS/NZS 1680.4:2001.
3.1 FACTORS CONTRIBUTING TO LIGHT LOSSES
Several factors contribute to light loss and the effect and magnitude of each varies with the type of activity and the location.
Clauses 3.2 to 3.5 (inclusive) outline the factors that contribute to light losses and cite typical examples of the type of data required to estimate the maintenance factor for a lighting system.
NOTE: Appendix B provides typical values of these factors in tabular form (Tables RI to 83 inclusive) to more clearly reveal the relationships between them.
3.2 LAMP LUMEN MAINTENANCE FACTOR (LLMF)
The output of all lamps will progressively decrease with use. The exact rate, however, depends upon many factors, including lamp type, control gear, switching cycles, dimming, electrical supply and thermal conditions. Table B2 shows typical examples for general information. As lamps of different types and lamps of the same general type from various manufacturers may exhibit widely differing characteristics, it is very important to obtain up-to-date data from the lamp manufacturers for estimating the maintenance factor and the maintenance program, particularly when using a new type of lamp.
3.3 LAMP SURVIVAL FACTOR (LSF)
Lamp survival is the probability of lamps continuing to operate for a given time. The survival rate depends upon many factors, including lamp type, control gear, switching cycles, dimming, electrical supply, thermal conditions and ribratior1. Failed lamps cause reductions in the illuminance and uniformity, hut the effect can be minimized by spot replacement of lamps. Table B2 shows typical values. For accurate data, the lamp manufacturer should always be consulted.
If the failure of one or more lamps compromises the maintenance illuminance required for the task(s), a maintenance plan should be in place that ensures the failed lamps are immediately replaced. Where such a spot lamp replacement program is adopted, a lamp survival factor of 1 may be assumed.
3.4 LUMINAIRE MAINTENANCE FACTOR (LMF)
Dirt on lamps and luminaires will generally cause the greatest light loss. In industrial lighting systems it is not uncommon to find 50% loss due to dirt build-up during long intervals between cleaning. The amount of light loss depends on the nature and density of airborne dirt, luminaire design, luminaire finish and lamp type. For example, areas vary as to the amount and type of dirt in the air; the amount of dirt in a foundry is greater than that found in an air conditioned office. But the amount and type of dirt in an office located near an industrial area is different from that in an office located in the country. The black dirt found in steelworks is most unlike the relatively light-coloured dust in bakeries. It is important to be able to recognize these variations when assessing light losses. Luminaire surfaces differ in their resistance to dirt accumulation and the nature of the dirt or dust involved will affect the level to which it adheres to the surface. Dust with high oil content will tend to adhere while dry dust can be blown off again. Some plastic materials and plastic paints can be statically charged and as a result actively attract dust.
The choice of luminaire type will depend on the nature of the dust involved.AS/NZS-1680.4 pdf download.

Download infomation Go to download
Note: Can you help me share this website on your Facebook or others? Many thanks!
AS/NZS 60079.5:2015 pdf free Free AS Standards

AS/NZS 60079.5:2015 pdf free

AS/NZS 60079.5:2015 pdf free.Explosive atmospheres Part 5: Equipment protection by powdered filling 'q'. 4.1.1.3 Containers intended to be opened for repair Electrical equipment, parts of electrical equipment, or Ex components that are designed to be repaired shall...
Get More
AS/NZS 60079.2:2015 pdf free Free AS Standards

AS/NZS 60079.2:2015 pdf free

AS/NZS 60079.2:2015 pdf free.AUSTRALIAN/NEW ZEAL AND STANDARD Explosive atmospheres. 5 Constructional requirements for pressurized enclosures 5.1 Enclosure The pressurized enclosure shall have a degree of protection in accordance with Table 2. For Level of Protection pxb with...
Get More
AS/NZS 5263.1.3:2016 pdf free Free AS Standards

AS/NZS 5263.1.3:2016 pdf free

AS/NZS 5263.1.3:2016 pdf free.Gas appliances Part 1.3: Gas space heating appliances. 2.1 SCOPE This Clause of AS 5263.0 applies. 2.2 GENERAL DESIGN REQUIREMENTS This Clause of AS 5263.0 applies, except as modified below. 2.2.13 IJesign olappliance base...
Get More

LEAVE A REPLY

Anonymous netizen Fill in information