AS 4852.1:2019 pdf free.Variable message signs Part 1: Fixed signs.
2.1 General
The sign shall be designed to ensure that it provides continuous and reliable operation for the roadside environment and wide environmental conditions in normal operation.
The sign and all mounting, support and access structures shall be constructed from durable materials treated to ensure optimum performance under prolonged exposure to atmospheric and site conditions prevalent in the geographical region in which they are intended to be used.
The design and installation of the sign, sign support structure, and associated equipment shall be vandal-resistant to ensure that it can withstand attempted damage to equipment and attempted unauthorized access to interiors of housings and casings by brute force.
NOTE I Appendix A gives further information about sign clearances and sign access. NOTE 2 AppendEx B gives guidance on placement of signs.
2.2 Design life
The designed operating life of the sign and its support structure shall be as follows:
(a) For the electrical system — not less than 15 years.
(b) For the sign enclosure — not less than 20 years.
(c) For roadside cabinet — not less than 20 years.
(d) For the sign mounting, support and access structures — not less than 50 years.
2.3 Markings and labels
2.3.1 General
All markings shall be clear, permanent, and weatherproof.
2.3.2 On sign controller
The following information shall be marked on the sign controller in a prominent position:
(a) Product/model name or brief description identifying the unit.
(b) Manufacturer’s name.
(c) Manufacturer’s type number.
A unique serial number.
(e) Description and rating of the primary power supply system, including nominal voltage. current and power consumption for operation.
(F) Relevant regulatory compliance marking (RCM).
2.3.3 On inside of sign controller housing
The following information shall be marked on the inside of the sign-controller housing, in a prominent position:
(a) Description and rating of the reservoir battery, including battery type, voltage and capacity.AS 4852.1 pdf download.

Download infomation Go to download
Note: Can you help me share this website on your Facebook or others? Many thanks!
AS/NZS 60079.5:2015 pdf free Free AS Standards

AS/NZS 60079.5:2015 pdf free

AS/NZS 60079.5:2015 pdf free.Explosive atmospheres Part 5: Equipment protection by powdered filling 'q'. 4.1.1.3 Containers intended to be opened for repair Electrical equipment, parts of electrical equipment, or Ex components that are designed to be repaired shall...
Get More
AS/NZS 60079.2:2015 pdf free Free AS Standards

AS/NZS 60079.2:2015 pdf free

AS/NZS 60079.2:2015 pdf free.AUSTRALIAN/NEW ZEAL AND STANDARD Explosive atmospheres. 5 Constructional requirements for pressurized enclosures 5.1 Enclosure The pressurized enclosure shall have a degree of protection in accordance with Table 2. For Level of Protection pxb with...
Get More
AS/NZS 5263.1.3:2016 pdf free Free AS Standards

AS/NZS 5263.1.3:2016 pdf free

AS/NZS 5263.1.3:2016 pdf free.Gas appliances Part 1.3: Gas space heating appliances. 2.1 SCOPE This Clause of AS 5263.0 applies. 2.2 GENERAL DESIGN REQUIREMENTS This Clause of AS 5263.0 applies, except as modified below. 2.2.13 IJesign olappliance base...
Get More

LEAVE A REPLY

Anonymous netizen Fill in information