AS 1172.4:2019 pdf free.Sanitary plumbing products Part 4: Washbasins.
1.5.5 Waste outlet
The waste outlet hole shall incorporate a flange recess that allows the installation of a waste fitting
conforming with AS 1589 or AS 2887 such that the fitting permits the drainage of the basin.
1.5.6 Support and rigidity
The washbasin shall provide for a means of secure support ensuring that when it is installed, no load is placed on the waste pipe or water connections. Support structures, fixings, fasteners, and stiffeners, where provided, shall have a life not less than that of the washbasin.
Washbasins which do not have a separate support structure shall be self-supporting, either from the base or from the flange as appropriate to the type of installation.
1.6 Washbasin strength and support test
With the exception of wall basins (see Clause 1.7), all washbasins when installed in accordance with the manufacturer’s instructions in the designed manner and filled to maximum capacity with water and with a 3O kg mass placed or hung on the middle of the front edge of the washbasin, shall, after a
period of 2 mm, show no sign of fracture, leakage or deformation greater than 5 mm. With the load removed, there shall be no permanent deformation greater than 1 mm and the washbasin shall show no signs of cracks, fracture or leakage.
1.7 Wall basin safety load test
When tested in accordance with Appendix B, wall basins shall show no sign of fracture, leakage or deformation greater than 5 mm. With the load removed, there shall be no permanent deformation greater than 1 mm and the wall basin shall show no signs of cracks, fracture or leakage. Fixings and brackets shall show no signs of failure.
NOTE Appendix B tests the integrity of the basin, fixed to a rigid wall. IL is not the intention to interpret this test as part of installation requirement.
1.8 Overflow prevention test
When tested in accordance with Appendix C, washbasins with an integral overflow, installed with any additional fittings supplied (cosmetic or other) shall prevent water in the bowl flowing over the rim.
The overflow opening shall freely drain to the waste outlet (below plug) or waste pipe system for the washbasin.
1.9 Marking
Each washbasin shall be permanently marked with the manufacturer’s name or trademark.
1.10 Labelling
Each washbasin shall be labelled or otherwise marked with model identification information.AS 1172.4 pdf download.

Download infomation Go to download
Note: Can you help me share this website on your Facebook or others? Many thanks!
AS/NZS 60079.5:2015 pdf free Free AS Standards

AS/NZS 60079.5:2015 pdf free

AS/NZS 60079.5:2015 pdf free.Explosive atmospheres Part 5: Equipment protection by powdered filling 'q'. 4.1.1.3 Containers intended to be opened for repair Electrical equipment, parts of electrical equipment, or Ex components that are designed to be repaired shall...
Get More
AS/NZS 60079.2:2015 pdf free Free AS Standards

AS/NZS 60079.2:2015 pdf free

AS/NZS 60079.2:2015 pdf free.AUSTRALIAN/NEW ZEAL AND STANDARD Explosive atmospheres. 5 Constructional requirements for pressurized enclosures 5.1 Enclosure The pressurized enclosure shall have a degree of protection in accordance with Table 2. For Level of Protection pxb with...
Get More
AS/NZS 5263.1.3:2016 pdf free Free AS Standards

AS/NZS 5263.1.3:2016 pdf free

AS/NZS 5263.1.3:2016 pdf free.Gas appliances Part 1.3: Gas space heating appliances. 2.1 SCOPE This Clause of AS 5263.0 applies. 2.2 GENERAL DESIGN REQUIREMENTS This Clause of AS 5263.0 applies, except as modified below. 2.2.13 IJesign olappliance base...
Get More

LEAVE A REPLY

Anonymous netizen Fill in information